    Brand Name : Huatec
    Model Number : HGM-BZ75
    Certification : ISO,CE
    Payment Terms : T/T, Western Union,Paypal
    Supply Ability : 500 set per month
    Delivery Time : 3-7 working days
    • Product Details
    • Company Profile

    75 Degree HGM-BZ75 Paint Gloss Meter For Paper Testing

    High precision 75 degree Paper Gloss Meter HGM-BZ75 for paper testing


    Gloss Meter Model HGM-BZ75 (75°intelligent )


    Standard

    International standard ISO-8254, TAPPI - T480, ASTM-C346, ASTM-D2457, DIN67530 and China standard GB8941.3

    The technical parameters follows China metrology standard JJG696-2002.


    Application
    BZ75 ° intelligent glossiness meter is follow ISO - 8254, TAPPI - T480, GB8941.3 standard manufacture high-precision, miniaturization, intelligent paper with glossiness plan, suitable for paper, etc, the paper is printed paper surface gloss surface lens to value measurement.


    Parameter

    The technical parameters up to JJG 696 (First-level standards).
    1. test range:0.0-300.0(Gs)
    1. test accuracy:<1.2(Gs)
    1. stability:0.4Gs/30min
    1. test caliber:16×48(mm)rectangular
    1. size:128×35×64 (mm)
    1. power:4.8V (Rechargeable battery inside)

    Features

    1. Small and light, real easy to be carried and used.
    2. 4.8V Rechargeable battery can be used for almost 60 hours and 10000 reading.
    3. High stability
    4. Long-term stable light source needs no replacing forever.
    5. Quartz crystal standard board, no excursion.

    6. Single-chip microcomputer control circuit, the new keystrokes, light and portable, a single calibration, intelligent calibration record values


    Use of equipment

    Press the power switch in the measurement mode, apparatus on the sample, the samples showed that the numerical point of view at this time of the gloss value (Gs). When the "angle/ shift" button, switch different angle measurement, the corresponding point of display lights. Whether measured by that point, when measured value greater than 300.0 Gs, shows that "OVER" word.

    When the electricity shortage Show "bAtt" words, at this time should be promptly charged with exclusive power rechargeable battery, charging devices plug into the mains socket on the side of charge, charging time in about four hours. Charging standards "⊕", charging the panel led by lit.


    Calibration:

    When standard equipment on board showed that the standard plate with the corresponding numerical point of difference is greater than the nominal value of 1.2 gloss units at the following methods should be calibrated:

    And measuring window on the black velvet board, press the "load switch / zero setting" button, this shows that numerical 0.0.

    Black glass plate instead of the standard black velvet boards, measuring instruments on the window, rather than pressing the "calibration / test" button to enter the set, and then display the "000" and the first "0" flashing. Rather than pressing the "angle / shift" key-flashing Move right, rather than pressing the "load switch / zero setting" key "flicker" of numerical change from 0-9-0 through the press "angle / shift" and "load switch / zero setting"key to making shows that numerical standards and black glass plate corresponding nominal value of the same, at this time rather than pressing the" calibration / test "button to complete the setup. And white ceramic standard equipment on board, show that numerical standards-and-white ceramic plate angle of the corresponding nominal value of the error should not exceed ± 1.2 gloss units, it should be considered standard plate dirt, and other issues. Which point of error of work, occupation which should be in work mode in accordance with the perspective of the above process of calibration. After the completion of the steps of the samples can be measured.


    Attention

    The equipment built four rechargeable batteries


    Standard Delivery

    Gloss meter1pc
    Instrument case1pc
    Standard board

    2pc

    A black board is used for the highlight calibration

    A white board is used for the low light calibration

    Battery charger1pc
    English instruction manual1pc
    Calibration certificate1pc

    HUATEC Gloss meter Reference angle for different application

    anglePoint of reference for (foreign) (China)

    Application



    20°

    DIN-67530

    ISO-2813 GB9754

    ASTM-D523

    ASTM-D2457 GB8807

    high gloss paint, ink, plastic.

    20°

    ASTM-D1834

    TAPPI-T653 GB8941.1

    high gloss stencil, cast coated paper.

    45°

    ISO-2767 GB8941-2surface of aluminum and aluminum oxide.
    45°

    ASTM-C346 GB/T3295

    ASTM-D2457 GB8807

    pottery, ceramic, plastic, plastic film, Stone
    45°JIS-E8741pottery, ceramic, plastic, plastic film, Stone

    60°

    ISO-2813 GB9754

    ASTM-C584 GB9966

    ASTM-D523

    DIN-67530

    ASTM-D2457 GB8807

    Mid-gloss paint, ink, plastics, ceramics, stone.



    75°

    ISO-8254

    TAPPI-T480 GB8941.3

    copperplate paper